EMC lab at ICAT is state-of-the-art facility which can cater to the automotive as well as non –automotive requirements. There are 02 anechoic chambers with adequate instrumentation to support the EMC requirements of automotive OEMs and suppliers. The non-automotive requirements include defence/military equipments, EV charging stations, railway sub-assemblies, medical equipments, industrial electronics, consumer electronics, wireless devices, household appliances, telecomm devices, radio equipments, multimedia devices, etc. Additionally the lab is also equipped to test/certify RFID tags & readers, ITS, ADAS, SLD, VAS, HVAC, ESA, etc. We also support with CE marking, multi-country approvals, WPC ETA, etc.

Capabilities

  • Radiated and Conducted emissions as per various CISPR standards.
  • Road Vehicles as per ISO 11451/SAE J1113.
  • Road Vehicle Components as per ISO 11452/SAE J1113.
  • Radiated Immunity as per IEC 61000-4-3.
  • Immunity to radiated magnetic fields as per IEC 61000-4-8/IEC 61000-4-9.
  • Conducted transient emissions on power leads, as per ISO 7637-2.
  • Immunity to conducted transients disturbances, as per ISO 7637-2/ISO 7637-3 (CCC and DCC).
  • Low-frequency conducted disturbances and signaling as per IEC 61000-2-2.
  • Immunity to Electrostatic Discharge (ESD) as per ISO 10605/IEC 61000-4-2.
  • Immunity to Fast transients as per IEC 61000-4-4.
  • Immunity to surges as per IEC 61000-4-5.
  • Immunity to Conducted disturbance induced by radio frequency fields as per IEC 61000-4-6.
  • Immunity to voltage dips & short interruptions as per IEC 61000-4-11/IEC 61000-4-29/IEC 61000-4-34.
  • Harmonic Current Emissions as per IEC 61000-3-2/IEC 61000-3-12.
  • Voltage Fluctuations and Flicker as per IEC 61000-3-3/IEC 61000-3-11.
  • Harmonics and Inter harmonics, low frequency immunity as per IEC 61000-4-13.
  • Voltage fluctuation immunity as per IEC 61000-4-14.
  • Ripple on DC input power port immunity as per IEC 61000-4-17.
  • Variation of power frequency immunity as per IEC 61000-4-28.
  • Electric Vehicle Charging Stations as per AIS 138/IEC 61581.
  • Medical Devices as per IEC 60601-1-2.
  • Defence Related devices as per MIL 461.
  • Radio Equipment as per EN 301 489.
  • Earth-moving and building construction machinery as per ISO 13766.
  • Agricultural Tractors as per AIS 168/ISO 14982.

Detailed Facility Update

  • Component Semi – Anechoic Chamber (CSAC) and Vehicle Semi – Anechoic Chamber (VSAC).
  • Capability upto 8 GHz for RE & 18 GHz for RI.
  • Overall Dimensions of CSAC: 8.5 m X 7 m X 6 m (L X W X H).
  • Overall Dimensions of VSAC: 30 m X 20 m X 10 m (L X W X H).
  • Both chambers have dedicated shielded control rooms with advanced instrumentation.
  • VSAC has a 11 m turntable, 4X4 chassis dynamometer with advanced electronic control system functions, for a vehicle up to 19 tons.
  • Maximum achievable speed on chassis dynamometer – 120 kmph
  • EMC troubleshooting, solutions & product development